1.
Rev. Soc. Bras. Med. Trop ; 53: e20190274, 2020. tab
Article in English | SES-SP, ColecionaSUS, LILACS | ID: biblio-1136815

ABSTRACT

Abstract INTRODUCTION: Rapid diagnostic tests (RDTs) are selected based on their performances. Here, we compared the diagnostic performance of different malaria RDTs. METHODS: Febrile patients were tested for malaria using Vikia Malaria Pf/Pan, Meriline-Meriscreen Pf/Pv/Pan, Right Sign Malaria Pf/Pan, and Right Sign Malaria Pf RDTs at Melen Regional Hospital in Gabon. RESULTS: In total, 120 of 274 tested children (43.8%) had malaria. The sensitivity was > 95% for all RDTs, while the specificity was > 85% for two tests. One test generated invalid tests (8%). CONCLUSIONS: Based on their performances, all tests except one may be recommended for malaria diagnosis.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Reagent Kits, Diagnostic , Malaria/diagnosis , Sensitivity and Specificity , Gabon
SELECTION OF CITATIONS